Skip to content

ECAM DOOR page

Back to ECAM System Display Overview

DOOR ECAM page

Number Name Variation Meaning
1 Oxygen pressure indication Green number The pressure is within the normal operating range.
Green pulse number The pressure is low.
Amber number The pressure is dangerously low.
2 REGUL LO PR Displayed Amber The oxygen pressure on the low-pressure circuit is low.
Hidden The oxygen pressure on the low-pressure circuit is within normal operating range.
3 CKPT OXY indication White The oxygen system is within normal operation.
Amber The oxygen pressure is low, or the OXYGEN CREW SUPPLY is off.
4 Door position indication Green box The door is closed and armed
Amber box The door is open.

Last update: August 28, 2023